/ can have -u; no end-of-day, no logfile, connect to master tickerplant / q chainedtick.q :5010 -p 5110 -t 1000 foo 2>&1 & / q chainedtick.q [host]:port[:usr:pwd] [-p 5110] [-t N] if[not system"p";system"p 5110"] \l tick/u.q if[system"t"; .z.ts:{.u.pub'[.u.t;value each .u.t];@[`.;.u.t;@[;`sym;`g#]0#]}; upd:{[t;x] t insert x;}] if[not system"t"; upd:{[t;x] .u.pub[t;x];}] / get the ticker plant port, default is 5010 .u.x:.z.x,(count .z.x)_enlist":5010" / init schema .u.rep:{(.[;();:;].)each x;} / connect to ticker plant for schema .u.init .u.rep(.u.m:hopen`$":",.u.x 0)".u.sub[`;`]" \ /test >q tick.k >q tick/ssl.q >q chainedtick.k /run >q tick.k sym . -p 5010 /tick >q tick/r.k ::5010 -p 5011 /rdb >q sym -p 5012 /hdb >q tick/ssl.q sym :5010 /feed >q chainedtick.k -p 5110 /chained tick